Waters XEVO TQ Mass Spectrometer LCMS Complete System

$85,000.00

This is our pre-owned Waters XEVO TQ Tandem Quadrupole MS Complete System. The system has been refurbished, calibrated and tuned.

The following are included:

  • Waters XEVO TQ Mass Spectrometer Detector
  • Waters Acquity I Class Binary Solvent Manager
  • Waters Acquity Sample Manager – FTN
  • Waters Acquity Column Manager
  • Waters LAC/E 32 Acquisition server including monitor, keyboard and mouse loaded with Masslynx 4.2
  • PEAK Nitrogen generator NM30LA-MS
  • Edwards Dry roughing pump XDS35i oil free
  • All tubings, cables and connection are included
  • Additional accessories including calibration and tuning solution
  • System hardware specification

1 in stock

Description

This is our pre-owned Waters XEVO TQ Tandem Quadrupole MS Complete System. The system has been refurbished, calibrated and tuned.

The following are included:

  • Waters XEVO TQ Mass Spectrometer Detector
  • Waters Acquity I Class Binary Solvent Manager
  • Waters Acquity Sample Manager – FTN
  • Waters Acquity Column Manager
  • Waters LAC/E 32 Acquisition server including monitor, keyboard and mouse loaded with Masslynx 4.2
  • PEAK Nitrogen generator NM30LA-MS
  • Edwards Dry roughing pump XDS35i oil free
  • All tubings, cables and connection are included
  • Additional accessories including calibration and tuning solution
  • System hardware specification
API Source and ionization mode High performance zspray dual orthogonal API sources: Multi mode source ESI/APCI/ESCi
Optimized gas flow dynamics for efficient ESI desolvation (supporting LC flow rates up to 2ml/min)
Tool-free source exchange
Vacuum isolation valve
Tool free access to customer serviceable elements
Plug and play probes
De-clustering con gas
Software control of gas flows and heating elements
Ion source transfer optics High efficiency hexapole ion guide
Mass analyzer two high resolution quadrupole analyzers (MS1/MS2), plus pre-filters to maximize resolution and transmission while preventing contamination of the main analyzers
Collision cell T-Wave enabled for optimal MS/MS performance at high data acquisition rates; ScanWave enabled for enhanced MS/MS spectral performance (product ion scanning); Software programmable gas control
Detector Low noise, off axis, long life photomultiplier detector; digital dynamic range up to 4×10^6
Vacuum system two air-cooled vacuum turbomolecular pumps evacuating the source and analyzer; one rotary backing pump
Dimensions 24×27.8×35.6”

System software specification

Software Masslynx 4.2, Open Lynx and TargetLynx Application Manager included
Intellistart technology System parameter checking and alerts
Integrated sample/calibrant delivery system + programmable divert valve
Automated mass calibration
Automated sample tuning
Automated SIR and MRM method development
LC/MS system check – automated on-column performance test
Quantification methods database Quanpedia – a database for storing and share user defined LC/MRM acquisistion methods and associated processing methods for the targeted quantification of named compounds.
Auto-Dwell feature for mrm acquisition dwell time, inter-channel delay time, and inter-scan delay time for individual channels in a multiple mrm experiment can be automatically assigned.
MRM acquisition window assignment multiple mrm experiment can be scheduled using retention time window to optimize the cycle time for each MRM channel.

Performance specs

Acquisition modes full scan MS
Product ion scan (scanwave enhanced)
Precursor ion scan
Constant neutral loss
Selected ion recording (SIR)
Multiple reaction monitoring (MRM)
Survey scan modes full scan MS triggered product ion scan
Precursor ion scan triggered ion scan
Constant neutral loss triggered product ion scan
Quan Qual mode MRM triggered ScanWave enhanced product ion spectral acquisition
Mass range 2 to 2048 m/z
Scan speed up to 10,000 Da/s
Examples of achievable acquisition rates: 10 scans/second (m/z 100 to 1000)

20 scans/second (m/z 50 to 500)

Mass stability mass drift is less than 0.1 amu over a 24hr period
Linearity of response the linearity of response relative to sample concentration, for a specified compound, is five orders of magnitude from the limit of detection
Polarity switching time 20 ms to switch between positive and negative ion modes
MS to MS/MS switching time 5ms
ESCi mode switching time 20 ms to switch between ESI and APCI
MRM acquisition rate minimum dwell time of 1 ms per MRM channel
Inter-channel cross talk The inter-channel cross talk between two MRM transitions, acquired using an MRM dwell time of 10 ms and inter-channel delay time of 10 ms, will be less than 0.02%
Number of MRM channels up to 16,384 MRM channels (512 functions, 323 channels per function) can be monitored in a single acquisition; up to 1024 MRM channels when operation in GLP/secure mode (32 functions, 32 channels per function)
Mass resolution automatically adjusted (intellistart) to desired resolution; (0.40 Da, 0.75 Da or 1.00 Da FWHM)
MRM sensitivity (ESI+) a 50 fg on-column injection of reserpine will give a chromatographic signal-to-noise greater than 500:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 609>195)
MRM sensitivity (ESI-) A 1 pg on-column injection of chloramphenicol will give a chromatographic signal-to-noise grated than 1,000:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 321>152)
MRM sensitivity (APCI+) A 10 pg on-column injection of 17-hydroxyprogesterone will give a chromatographic signal-to-noise greater than 100:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 331>109)

 

We offer shipping solutions worldwide, for quotes please contact us.

Additional information

Weight 200 kg
Dimensions 40 × 40 × 22 cm