Waters XEVO TQ Mass Spectrometer LCMS Complete System
$85,000.00
This is our pre-owned Waters XEVO TQ Tandem Quadrupole MS Complete System. The system has been refurbished, calibrated and tuned.
The following are included:
- Waters XEVO TQ Mass Spectrometer Detector
- Waters Acquity I Class Binary Solvent Manager
- Waters Acquity Sample Manager – FTN
- Waters Acquity Column Manager
- Waters LAC/E 32 Acquisition server including monitor, keyboard and mouse loaded with Masslynx 4.2
- PEAK Nitrogen generator NM30LA-MS
- Edwards Dry roughing pump XDS35i oil free
- All tubings, cables and connection are included
- Additional accessories including calibration and tuning solution
- System hardware specification
1 in stock
Description
This is our pre-owned Waters XEVO TQ Tandem Quadrupole MS Complete System. The system has been refurbished, calibrated and tuned.
The following are included:
- Waters XEVO TQ Mass Spectrometer Detector
- Waters Acquity I Class Binary Solvent Manager
- Waters Acquity Sample Manager – FTN
- Waters Acquity Column Manager
- Waters LAC/E 32 Acquisition server including monitor, keyboard and mouse loaded with Masslynx 4.2
- PEAK Nitrogen generator NM30LA-MS
- Edwards Dry roughing pump XDS35i oil free
- All tubings, cables and connection are included
- Additional accessories including calibration and tuning solution
- System hardware specification
| API Source and ionization mode | High performance zspray dual orthogonal API sources: Multi mode source ESI/APCI/ESCi | 
| Optimized gas flow dynamics for efficient ESI desolvation (supporting LC flow rates up to 2ml/min) | |
| Tool-free source exchange | |
| Vacuum isolation valve | |
| Tool free access to customer serviceable elements | |
| Plug and play probes | |
| De-clustering con gas | |
| Software control of gas flows and heating elements | |
| Ion source transfer optics | High efficiency hexapole ion guide | 
| Mass analyzer | two high resolution quadrupole analyzers (MS1/MS2), plus pre-filters to maximize resolution and transmission while preventing contamination of the main analyzers | 
| Collision cell | T-Wave enabled for optimal MS/MS performance at high data acquisition rates; ScanWave enabled for enhanced MS/MS spectral performance (product ion scanning); Software programmable gas control | 
| Detector | Low noise, off axis, long life photomultiplier detector; digital dynamic range up to 4×10^6 | 
| Vacuum system | two air-cooled vacuum turbomolecular pumps evacuating the source and analyzer; one rotary backing pump | 
| Dimensions | 24×27.8×35.6” | 
System software specification
| Software | Masslynx 4.2, Open Lynx and TargetLynx Application Manager included | 
| Intellistart technology | System parameter checking and alerts | 
| Integrated sample/calibrant delivery system + programmable divert valve | |
| Automated mass calibration | |
| Automated sample tuning | |
| Automated SIR and MRM method development | |
| LC/MS system check – automated on-column performance test | |
| Quantification methods database | Quanpedia – a database for storing and share user defined LC/MRM acquisistion methods and associated processing methods for the targeted quantification of named compounds. | 
| Auto-Dwell feature for mrm acquisition | dwell time, inter-channel delay time, and inter-scan delay time for individual channels in a multiple mrm experiment can be automatically assigned. | 
| MRM acquisition window assignment | multiple mrm experiment can be scheduled using retention time window to optimize the cycle time for each MRM channel. | 
Performance specs
| Acquisition modes | full scan MS | 
| Product ion scan (scanwave enhanced) | |
| Precursor ion scan | |
| Constant neutral loss | |
| Selected ion recording (SIR) | |
| Multiple reaction monitoring (MRM) | |
| Survey scan modes | full scan MS triggered product ion scan | 
| Precursor ion scan triggered ion scan | |
| Constant neutral loss triggered product ion scan | |
| Quan Qual mode | MRM triggered ScanWave enhanced product ion spectral acquisition | 
| Mass range | 2 to 2048 m/z | 
| Scan speed | up to 10,000 Da/s | 
| Examples of achievable acquisition rates: | 10 scans/second (m/z 100 to 1000) 20 scans/second (m/z 50 to 500) | 
| Mass stability | mass drift is less than 0.1 amu over a 24hr period | 
| Linearity of response | the linearity of response relative to sample concentration, for a specified compound, is five orders of magnitude from the limit of detection | 
| Polarity switching time | 20 ms to switch between positive and negative ion modes | 
| MS to MS/MS switching time | 5ms | 
| ESCi mode switching time | 20 ms to switch between ESI and APCI | 
| MRM acquisition rate | minimum dwell time of 1 ms per MRM channel | 
| Inter-channel cross talk | The inter-channel cross talk between two MRM transitions, acquired using an MRM dwell time of 10 ms and inter-channel delay time of 10 ms, will be less than 0.02% | 
| Number of MRM channels | up to 16,384 MRM channels (512 functions, 323 channels per function) can be monitored in a single acquisition; up to 1024 MRM channels when operation in GLP/secure mode (32 functions, 32 channels per function) | 
| Mass resolution | automatically adjusted (intellistart) to desired resolution; (0.40 Da, 0.75 Da or 1.00 Da FWHM) | 
| MRM sensitivity (ESI+) | a 50 fg on-column injection of reserpine will give a chromatographic signal-to-noise greater than 500:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 609>195) | 
| MRM sensitivity (ESI-) | A 1 pg on-column injection of chloramphenicol will give a chromatographic signal-to-noise grated than 1,000:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 321>152) | 
| MRM sensitivity (APCI+) | A 10 pg on-column injection of 17-hydroxyprogesterone will give a chromatographic signal-to-noise greater than 100:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 331>109) | 
We offer shipping solutions worldwide, for quotes please contact us.
Additional information
| Weight | 200 kg | 
|---|---|
| Dimensions | 40 × 40 × 22 cm | 