Agilent 1100 HPLC Complete System Cannabis Cannabinoid Potency
Original price was: $12,190.00.$9,800.00Current price is: $9,800.00.
This is one of our pre-owned Agilent 1100 HPLC systems specialized in Cannabinoid potency testing. This system has been decommissioned by an established Cannabis testing organization which was closing its local laboratory. The instrument is therefore adequately equipped to run cannabis samples. All the components were tested and are in great working condition. The computer contains manuals and methods specially designed for the cannabis industry.
1 in stock (can be backordered)
Description
This is one of our pre-owned Agilent 1100 HPLC systems specialized in Cannabinoid potency testing. This system has been decommissioned by an established Cannabis testing organization which was closing its local laboratory. The instrument is therefore adequately equipped to run cannabis samples.
All the components were tested and are in great working condition. The computer contains manuals and methods specially designed for the cannabis industry.
The following modules are included:
– G1314A VWD Variable Wavelength Detector
- Wavelength range: 190-600 nm
- Light source: Deuterium lamp
- Short term noise (ASTM): ± 0.75 × 10-5AU at 254 nm
- Drift: 3 × 10-4AU/hr at 254 nm
- Linear Absorbance range: >2 AU (5%) upper limit
- Wavelength accuracy: ± 1 nm
- Slit width: 1, 2, 4 , 8, 16 nm
- Band Width: 6.5 nm typical
- Diode Width: <1 nm
– G1311A Quat Pump
- Hydraulic system Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve
- Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments
- Flow range: 0.2 – 10.0 ml/min
- Flow Accuracy: ± 1% or 10 μl/min whatever is greater
- Pressure Operating range: 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min
Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min - Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all
pressures > 1 MPa (10 bar) - Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
- Composition Range 0 – 95 % or 5 – 100 %, user selectable
– G1313A Autosampler
- Injection Range: 0.1 – 100 µl in 0.1 µl increments
- Replicate Injections: 1 – 99 from one vial
- Precision: < 0.5 % RSD of peak areas from 5 – 100 µl / < 1 % RSD of peak areas from 1 – 5 µl
- Minimum Sample Volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
- Carryover: < 0.1 %, < 0.05 % with external needle cleaning
- Sample Viscosity Range: 0.2 – 50 cp
- Sample Capacity: 100 × 2-ml vials in 1 tray; 40 × 2-ml vials in ½ tray; 15 × 6-ml vials in ½ tray
- Weight: 31.3 lbs (14.2 kg)
- Dimensions (W × H × D): 13.5 × 8 × 17 inches (345 × 200 × 435 mm)
– G1316A Thermostatted Column Compartment with a new column.
- Two heat exchangers for solvent pre-heating, automated column identification module and CAN cable.
– G1379A Degasser
- Maximum flow rate: 0 – 10 ml/min per channel 5 – 10 ml/min at reduced degassing performance
- Number of channels: 4
- Internal volume per channel: Typically 1 ml per channel
- Materials in contact with solvent PTFE, FEP,PEEK
- pH range1–14
– Solvent Tray
– All tubings, capillaries, power & communication cables
– The system is run on Chemstation data acquisition software, configured and ready to run.
*Note: Licenses for Agilent’s software products are not transferable. Any customer who purchases Agilent products are advised to contact Agilent for license requirements.
All brand names and logos depicted at our website are the trademarks of the respective companies. We are not their representatives nor authorized resellers. The discounted system does not include the column and the capillaries.
This system is available for worldwide shipping, for quotes to countries other than the US and Canada; please contact us.
Additional information
Weight | 125 kg |
---|---|
Dimensions | 45 × 20 × 25 cm |
Reviews
There are no reviews yet.