Thermo Quantum Ultra LC/MS/MS Triple Quad Cannabis Pesticide Herbicide Testing with Agilent 1100
$41,000.00
This is our pre-owned Thermo Quantum Ultra LC/MS/MS Triple Quad Cannabis Pesticide Herbicide Testing with Agilent 1100 HPLC specialized in Cannabinoid potency testing. It is completely refurbished, and is part of our new arrival from a top edge cannabinoid research facility where it was mainly used for pesticide testing.
1 in stock (can be backordered)
Description
This is our pre-owned Thermo Quantum Ultra LC/MS/MS Triple Quad Cannabis Pesticide Herbicide Testing with Agilent 1100 HPLC specialized in Cannabinoid potency testing. It is completely refurbished, and a part of our new arrival from a top edge cannabinoid research facility. There, the system was mainly used for pesticide testing. All components are tested and in great working condition. The computer contains manuals and methods specially designed for the cannabis industry.
Thermo LC/MS/MS with Agilent 1100 Specifications:
- – HESI II Source
- – Resolution up to 7,500 at m/z 508
- – Mass Range: m/z 30–1500
- – ESI ionization mode
- – Two Roughing pump Edwards E2M30
Agilent 1100 HPLC modules included:
-
G1314A VWD Variable Wavelength Detector
- Wavelength range: 190-600 nm
- Light source: Deuterium lamp
- Short term noise (ASTM): ± 0.75 × 10-5AU at 254 nm
- Drift: 3 × 10-4AU/hr at 254 nm
- Linear Absorbance range: >2 AU (5%) upper limit
- Wavelength accuracy: ± 1 nm
- Slit width: 1, 2, 4 , 8, 16 nm
- Band Width: 6.5 nm typical
- Diode Width: <1 nm
-
G1311A Quat Pump
- Hydraulic system Dual plunger in series pump with proprietary servo-controlled variable stroke drive, floating plungers and active inlet valve
- Setable flow range: 0.001 – 10 ml/min, in 0.001 ml/min increments
- Flow range: 0.2 – 10.0 ml/min
- Flow Accuracy: ± 1% or 10 μl/min whatever is greater
- Pressure Operating range: 0 – 40 MPa (0 – 400 bar, 0 – 5880 psi) up to 5 ml/min
Operating range 0 – 20 MPa (0 – 200 bar, 0 – 2950 psi) up to 10 ml/min - Pressure pulsation: < 2 % amplitude (typically < 1 %), at 1 ml/min isopropanol, at all
pressures > 1 MPa (10 bar) - Recommended pH range: 1.0 – 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel
- Composition Range 0 – 95 % or 5 – 100 %, user selectable
-
G1313A Autosampler
- Injection Range: 0.1 – 100 µl in 0.1 µl increments
- Replicate Injections: 1 – 99 from one vial
- Precision: < 0.5 % RSD of peak areas from 5 – 100 µl / < 1 % RSD of peak areas from 1 – 5 µl
- Minimum Sample Volume: 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvial
- Carryover: < 0.1 %, < 0.05 % with external needle cleaning
- Sample Viscosity Range: 0.2 – 50 cp
- Sample Capacity: 100 × 2-ml vials in 1 tray; 40 × 2-ml vials in ½ tray; 15 × 6-ml vials in ½ tray
- Weight: 31.3 lbs (14.2 kg)
- Dimensions (W × H × D): 13.5 × 8 × 17 inches (345 × 200 × 435 mm)
-
G1316A Thermostatted Column Compartment with a new column.
- Two heat exchangers for solvent pre-heating, automated column identification module and CAN cable.
-
G1379A Degasser
- Maximum flow rate: 0 – 10 ml/min per channel 5 – 10 ml/min at reduced degassing performance
- Number of channels: 4
- Internal volume per channel: Typically 1 ml per channel
- Materials in contact with solvent PTFE, FEP,PEEK
- pH range1–14
-
Solvent tray, tubings, capillaries, power, and communication cables
For shipping quotes to countries other than the US and Canada, please contact us.
*Note: Licenses for Agilent’s software products are not transferable. Any customer who purchases Agilent products are advised to contact Agilent for license requirements. All brand names and logos depicted at our website are the trademarks of the respective companies. We are not their representatives nor authorized resellers.
Additional information
Weight | 350 kg |
---|---|
Dimensions | 45 × 45 × 40 cm |
Reviews