Waters XEVO TQ Mass Spectrometer LCMS Complete System
$85,000.00
This is our pre-owned Waters XEVO TQ Tandem Quadrupole MS Complete System. The system has been refurbished, calibrated and tuned.
The following are included:
- Waters XEVO TQ Mass Spectrometer Detector
- Waters Acquity I Class Binary Solvent Manager
- Waters Acquity Sample Manager – FTN
- Waters Acquity Column Manager
- Waters LAC/E 32 Acquisition server including monitor, keyboard and mouse loaded with Masslynx 4.2
- PEAK Nitrogen generator NM30LA-MS
- Edwards Dry roughing pump XDS35i oil free
- All tubings, cables and connection are included
- Additional accessories including calibration and tuning solution
- System hardware specification
1 in stock
Description
This is our pre-owned Waters XEVO TQ Tandem Quadrupole MS Complete System. The system has been refurbished, calibrated and tuned.
The following are included:
- Waters XEVO TQ Mass Spectrometer Detector
- Waters Acquity I Class Binary Solvent Manager
- Waters Acquity Sample Manager – FTN
- Waters Acquity Column Manager
- Waters LAC/E 32 Acquisition server including monitor, keyboard and mouse loaded with Masslynx 4.2
- PEAK Nitrogen generator NM30LA-MS
- Edwards Dry roughing pump XDS35i oil free
- All tubings, cables and connection are included
- Additional accessories including calibration and tuning solution
- System hardware specification
API Source and ionization mode | High performance zspray dual orthogonal API sources: Multi mode source ESI/APCI/ESCi |
Optimized gas flow dynamics for efficient ESI desolvation (supporting LC flow rates up to 2ml/min) | |
Tool-free source exchange | |
Vacuum isolation valve | |
Tool free access to customer serviceable elements | |
Plug and play probes | |
De-clustering con gas | |
Software control of gas flows and heating elements | |
Ion source transfer optics | High efficiency hexapole ion guide |
Mass analyzer | two high resolution quadrupole analyzers (MS1/MS2), plus pre-filters to maximize resolution and transmission while preventing contamination of the main analyzers |
Collision cell | T-Wave enabled for optimal MS/MS performance at high data acquisition rates; ScanWave enabled for enhanced MS/MS spectral performance (product ion scanning); Software programmable gas control |
Detector | Low noise, off axis, long life photomultiplier detector; digital dynamic range up to 4×10^6 |
Vacuum system | two air-cooled vacuum turbomolecular pumps evacuating the source and analyzer; one rotary backing pump |
Dimensions | 24×27.8×35.6” |
System software specification
Software | Masslynx 4.2, Open Lynx and TargetLynx Application Manager included |
Intellistart technology | System parameter checking and alerts |
Integrated sample/calibrant delivery system + programmable divert valve | |
Automated mass calibration | |
Automated sample tuning | |
Automated SIR and MRM method development | |
LC/MS system check – automated on-column performance test | |
Quantification methods database | Quanpedia – a database for storing and share user defined LC/MRM acquisistion methods and associated processing methods for the targeted quantification of named compounds. |
Auto-Dwell feature for mrm acquisition | dwell time, inter-channel delay time, and inter-scan delay time for individual channels in a multiple mrm experiment can be automatically assigned. |
MRM acquisition window assignment | multiple mrm experiment can be scheduled using retention time window to optimize the cycle time for each MRM channel. |
Performance specs
Acquisition modes | full scan MS |
Product ion scan (scanwave enhanced) | |
Precursor ion scan | |
Constant neutral loss | |
Selected ion recording (SIR) | |
Multiple reaction monitoring (MRM) | |
Survey scan modes | full scan MS triggered product ion scan |
Precursor ion scan triggered ion scan | |
Constant neutral loss triggered product ion scan | |
Quan Qual mode | MRM triggered ScanWave enhanced product ion spectral acquisition |
Mass range | 2 to 2048 m/z |
Scan speed | up to 10,000 Da/s |
Examples of achievable acquisition rates: | 10 scans/second (m/z 100 to 1000)
20 scans/second (m/z 50 to 500) |
Mass stability | mass drift is less than 0.1 amu over a 24hr period |
Linearity of response | the linearity of response relative to sample concentration, for a specified compound, is five orders of magnitude from the limit of detection |
Polarity switching time | 20 ms to switch between positive and negative ion modes |
MS to MS/MS switching time | 5ms |
ESCi mode switching time | 20 ms to switch between ESI and APCI |
MRM acquisition rate | minimum dwell time of 1 ms per MRM channel |
Inter-channel cross talk | The inter-channel cross talk between two MRM transitions, acquired using an MRM dwell time of 10 ms and inter-channel delay time of 10 ms, will be less than 0.02% |
Number of MRM channels | up to 16,384 MRM channels (512 functions, 323 channels per function) can be monitored in a single acquisition; up to 1024 MRM channels when operation in GLP/secure mode (32 functions, 32 channels per function) |
Mass resolution | automatically adjusted (intellistart) to desired resolution; (0.40 Da, 0.75 Da or 1.00 Da FWHM) |
MRM sensitivity (ESI+) | a 50 fg on-column injection of reserpine will give a chromatographic signal-to-noise greater than 500:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 609>195) |
MRM sensitivity (ESI-) | A 1 pg on-column injection of chloramphenicol will give a chromatographic signal-to-noise grated than 1,000:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 321>152) |
MRM sensitivity (APCI+) | A 10 pg on-column injection of 17-hydroxyprogesterone will give a chromatographic signal-to-noise greater than 100:1 (LC mobile phase flow rate of 0.8ml/min, MRM transition m/z 331>109) |
We offer shipping solutions worldwide, for quotes please contact us.
Additional information
Weight | 200 kg |
---|---|
Dimensions | 40 × 40 × 22 cm |