Shimadzu Prominence 20 HPLC UFLC System Including Software
Original price was: $24,500.00.$23,000.00Current price is: $23,000.00.
This is a pre-owned complete Shimadzu UFLC, that offers genuine high throughput, system in excellent condition.
The system has been regularly serviced and maintained.
This system is available for worldwide shipping, for shipping quotes to countries other than the US and Canada; please inquire.
1 in stock
Description
This is a pre-owned complete Shimadzu HPLC system in excellent condition.
The system contains the following components, in addition to the software LABSolution installed on a computer and the cables:
-Shimadzu Prominence CTO-20A Column Oven (ser. L20214850740)
-Shimadzu RF-20A Prominence Fluorescence detector, HPLC06-05, cat.no. 228-45147-42, ser. L20494850028
-Shimadzu Prominence SPD-20A Ultraviolet/vis Detector, ser. L201345851038 US D, 120V, 50/60Hz, 160Va
-Shimadzu Prominence SIL-20AC HT Autosampler (Serial Number:L20174350015 US A)
-Shimadzu Prominence LC-20AD Pump (Serial Number: L201048-59059 )
-Shimadzu Prominence DGU-20A5 Degasser (Serial Number SSI-5-1814)
-Shimadzu Prominence Reservoir Tray
-Computer with the software LabSolution with the dongle
READY TO SHIP
The SIL-20A Series autosamplers achieve unparalleled speed, with a sample injection movement of just 10 seconds. Prominence reduces the total analysis cycle time, not simply the time for the HPLC analysis itself. Prominence is an HPLC system that offers genuine high throughput. The extremely low sample carryover of the Prominence SIL-20A autosampler series is one reason for the superior analytical data. Even under severe UFLC analysis conditions, the excellent basic performance of the Prominence SIL-20A autosampler series generates high quality data.
The Shimadzu Prominence SPD-20A detector is a high-performance liquid chromatography (HPLC) detector designed for analytical and preparative separations. Here are some specifications of the SPD-20A:
- Detection Principle: The SPD-20A uses a photodiode array (PDA) detector, which employs a diode array to detect and measure the intensity of light at multiple wavelengths simultaneously, allowing for rapid and accurate detection of analytes.
- Wavelength Range: The SPD-20A has a wide wavelength range of 190-800 nm, making it suitable for a wide range of applications and allowing for detection of analytes with varying absorption characteristics.
- Wavelength Accuracy and Precision: The wavelength accuracy of the SPD-20A is ±1 nm, and the wavelength precision is ±0.1 nm, ensuring reliable and precise wavelength settings for accurate detection.
- Data Acquisition Rate: The SPD-20A has a high data acquisition rate of up to 80 data points per second, allowing for real-time monitoring of elution profiles and precise peak detection.
- Flow Cell Volume: The flow cell of the SPD-20A has a small volume of 10 µL, which minimizes band broadening and allows for high-resolution separation.
- Signal-to-Noise Ratio: The SPD-20A has a signal-to-noise ratio of 2500:1 or higher, providing high sensitivity and reliable detection of low-concentration analytes.
- Operating Modes: The SPD-20A offers various operating modes, including single-wavelength, multi-wavelength, and spectral scanning modes, allowing for versatile detection options depending on the analysis requirements.
- Control and Connectivity: The SPD-20A can be controlled via a user-friendly interface with a color LCD display and offers various connectivity options, such as USB and LAN, for data transfer and instrument control.
- Compliance: The SPD-20A complies with various regulatory requirements, including FDA 21 CFR Part 11, ensuring data integrity and security for regulated applications.
The LC-20AD Series offers pumping flow rates from 100 nL/minute and achieves the highly stable flow-rate performance demanded by UFLC, LC/MS, and GPC. The LC-20AD Series features pump heads with just 10 μL plunger volume equipped in parallel. The parallel double-plunger mechanism simultaneously compensates the pulsation for each pump head. It achieves high pumping accuracy across a broad flow-rate range from the micro to the semi-preparative scale.
The wide dynamic range and high sensitivity make SPD-20A UV-VIS detectors powerful tools for determining trace impurities.
The Shimadzu Prominence RF-20A detector is a high-performance liquid chromatography (HPLC) detector that is designed for fluorescence detection. Here are some key specifications of the RF-20A:
- Detection Principle: The RF-20A detector uses fluorescence detection, which is a highly sensitive and selective technique that relies on the emission of light from analytes after excitation with a specific wavelength of light.
- Wavelength Range: The RF-20A has a wide wavelength range for excitation and emission wavelengths, allowing for versatile detection of fluorescent compounds. The excitation wavelength range is typically 200-700 nm, and the emission wavelength range is typically 250-900 nm.
- Sensitivity: The RF-20A offers high sensitivity, with a low noise level and high signal-to-noise ratio, allowing for detection of trace amounts of fluorescent analytes in complex samples.
- Data Acquisition Rate: The RF-20A has a fast data acquisition rate of up to 100 data points per second, enabling real-time monitoring of chromatographic peaks and accurate peak detection.
- Operating Modes: The RF-20A offers various operating modes, including single-wavelength, multi-wavelength, and time-programmed modes, allowing for flexible and customized detection options based on the analysis requirements.
- Cell Volume: The RF-20A typically has a small cell volume, which minimizes band broadening and allows for high-resolution separation.
- Lamp Options: The RF-20A can be equipped with different types of lamps, such as deuterium (D2) lamps for UV excitation or xenon (Xe) lamps for wider wavelength range, providing flexibility for different fluorescence detection needs.
- Control and Connectivity: The RF-20A can be controlled via a user-friendly interface with a color LCD display and offers various connectivity options, such as USB and LAN, for data transfer and instrument control.
- Compliance: The RF-20A complies with various regulatory requirements, including FDA 21 CFR Part 11, ensuring data integrity and security for regulated applications.
*Note: All brand names and logos depicted at our website are the trademarks of the respective companies. We are not their representatives nor authorized resellers.
Additional information
Weight | 120 kg |
---|---|
Dimensions | 100 × 120 × 150 cm |
Reviews
There are no reviews yet.